top of page

Chemical System Solution

General Manufacturing

Solutions for Wastewater Treatment & Management

FRC Components

Reactor Tanks, Open-Style DAF

Project Description

FRC designed a solution for a major producer of synthetic rubber. The plant was generating over 1 MGD of wastewater and need to reduce the high amounts of solids, oils, and grease being sent to their biological system. FRC provided a rental DAF, flocculator, and chemical dosing skid that provided an immediate solution and yielded excellent results. Because of the ever-changing wastewater composition and flows, FRC engineered the permanent solution with reactor tanks in lieu of a flocculator.

The FRC Solution

  • Reactor Tanks – Coagulant, pH adjustment, and polymer dosed to precipitate the high toxicity, colloidal solids

  • DAF – Float the precipitated solids, yielding wastewater well-suited for further treatment

Parameter

Design Data

Flow (gpm)

700

Flow (m3/h)

159

TSS (mg/L)

2450

O&G (mg/L)

2500


Design Data


bottom of page